JoyOne factory · stair layout

Stair Stringer Calculator: Rise, Run, Throat Depth and Cut List

Measure the total rise once. This works out the riser count, the tread run, how long the stringer is on the slope, how much wood is left under the notch, and where to hold the framing square.

Live redraw IRC checks Framing-square setting Printable cut list

Stair stringer calculator

7 risers · 6 treads

6 7/8" step · 10" tread · throat 5 5/8"

in

Grade to finished deck, or floor to floor. Also accepts 4' 0" or 1220 mm.

in
in

Nosing to nosing. The code minimum is 10 in.

in

Takes the same amount off the bottom riser cut.

Check an existing stair, headroom and nosing
in

Required between 3/4 in and 1 1/4 in when the tread is under 11 in.

in

Tallest riser minus shortest. Leave at 0 for a new layout.

in

Optional. Measured from the nosing line straight up.

Everything is computed in this tab. Nothing you type is uploaded, and the share link keeps the numbers after the #.

Every limit on this page passes7 risers · 6 treads · 6 ⅞" step · 5' 0" run

Risers
76 treads cut in the stringer
Unit rise
6 7/8"174 mm
Unit run
10"254 mm
Total run
5' 0"1524 mm
Stringer length
6' 4 13/16"1952 mm
Throat depth
5 5/8"on a 2x12
First riser cut
5 3/8"unit rise − tread thickness
Stair angle
34.4°2R + T = 23.71 in

Same rise, different count — tap one to redraw

A stair rising 4' 0" over 5' 0": 7 risers at 6 7/8" and 6 treads at 10". The stringer is 6' 4 13/16" long on the slope, cut from a 2x12, and the throat under the first notch is 5 5/8".throat 5 ⅝"48"run 60"6 ⅞1034.4° from level
Cut stringer on a 2x12: 7 risers, 6 treads, 6' 4 13/16" on the slope.

Framing square setting

Hold the square with 6 ⅞ on the tongue (riser) and 10 on the blade (tread). Step it up the board, marking the same face every time.

Bottom plumb cut: unit rise minus tread thickness = 6 ⅞ − 1 ½ = 5 ⅜. The tread sits on top, so the first step still measures the full unit rise when you stand on it.

Code checks

  • Riser 6 7/8" against the 7 3/4 in maximum

    48 in over 7 risers is 6.857 in per step.

    IRC R311.7.5.1

  • Measured riser spread 0" against the 3/8 in limit

    A layout cut from one number has no spread at all; the check matters when you measure an existing stair.

    IRC R311.7.5.1

  • Tread 10" against the 10 in minimum

    6 treads at 10" gives a 5' 0" total run.

    IRC R311.7.5.2

  • Nosing 1" against the 3/4 in to 1 1/4 in range

    A 10" tread needs a nosing; 1" sits inside the range.

    IRC R311.7.5.3

  • Width 3' 0" against the 36 in minimum

    3 stringers at 1' 6" on centre.

    IRC R311.7.1

  • Flight rise 4' 0" against the 12 ft limit

    One flight can carry this rise without an intermediate landing.

    IRC R311.7.3

  • Headroom not measured

    Measure from the nosing line straight up to the floor opening; nothing below 6 ft 8 in passes.

    IRC R311.7.2

  • Throat 5 5/8" against the 5 in working depth

    2x12 leaves 5 5/8" of solid wood under the notch, at or above the 5.1 in depth AWC analyses.

    AWC DCA 6

  • Stringer stock 2x12

    At least a 2x12, as DCA 6 requires for deck stairs; at least three cut stringers.

    AWC DCA 6

  • Horizontal span 5' 0" against 13 ft 3 in

    Inside the 13 ft 3 in horizontal span DCA 6 permits for solid 2x12 stringers.

    AWC DCA 6

  • Handrail required on at least one side

    Four or more risers means a graspable handrail, set 34 to 38 in above the nosing line.

    IRC R311.7.8

Comfort: Shallow — a long, shuffling step — 2R + T is 23.71 in.

This is a layout calculator, not a code authority. Every limit shown is quoted from the IRC or from AWC DCA 6, but your state, county or city adopts one edition of the code and may amend it, and an inspector can read a detail differently. Confirm the numbers with your local building department before you cut lumber, and follow the manufacturer for engineered connectors, composite treads and guards.

Three rises, worked out

The same engine that runs in the browser produced this table at build time, so the examples cannot drift from the calculator above.

Worked examples on this page, generated by the same engine the calculator runs
RiseRisersUnit riseTreadsTotal runStringerThroatMaterial
4' 0" rise76 7/8"65' 0"6' 4 13/16"5 5/8"3 stringers
5' 0" rise87 1/2"75' 10"7' 8 3/16"5 1/4"3 stringers
6' 0" rise107 3/16"97' 6"9' 7 1/4"5 7/16"3 stringers

Produced at build time by the same function the page runs, so the examples cannot drift from the calculator above.

Measure the total rise, not the slope

The total rise is one number: how far the stair climbs from the surface you stand on to the surface you end on. On a deck stair that is from grade at the foot of the stair to the top of the finished decking, not to the top of the rim joist. Decking is usually 1 in or 1 1/4 in thick, and leaving it out is the most common way a first step ends up short by exactly that much. On an interior stair it is from the finished floor at the bottom to the finished floor at the top, so engineered hardwood, tile underlayment and a threshold all count.

Do not measure along the stringer. A tape hooked at the bottom and read where it crosses the deck is reading the hypotenuse, which on a 7 1/2 in by 10 in stair is about 25 percent longer than the rise and will put you a riser out. Instead, drop a plumb line or a level line from the deck edge to a stake at the foot of the stair, mark the deck height on the stake, and measure vertically from that mark to the ground. If the ground slopes, measure at the point where the bottom of the stringer will actually bear, and if the ground falls away, expect to build a pad.

Measure on the finished surfaces and measure twice from two corners. A deck that is 1/2 in out of level across its width still gives one stair a single rise, and that number is the height at the stringer you are cutting, not the average of the deck. Where the stair meets a door, the door swing and the landing depth can force the layout more than the arithmetic does, which is why the landing page exists.

The riser count comes first, and 7 1/2 in is the number to aim at

Divide the total rise by 7 1/2 in, round the answer up, and you have a starting count. A 48 in rise divided by 7.5 is 6.4, so the stair takes 7 risers, and each one is 48 ÷ 7 = 6.857 in, or about 6 7/8 in. Rounding up rather than down matters: 6 risers would put every step at 8 in, past the 7 3/4 in maximum in IRC R311.7.5.1, and the stair would fail inspection before anyone walked it. The calculator always starts with the compliant count nearest your target, and it shows the neighbouring counts so you can trade a steeper step against a shorter footprint.

Riser count is not the same as tread count. The top of the stair is the deck or the floor, and that surface is the last tread, so a 7 riser stair has 6 treads cut into the stringer. Nothing is missing: the seventh tread is the deck you are standing on. This is why a calculator that reports "steps" and a carpenter who counts treads often disagree by one, and it is why the step page shows both numbers, labelled.

A steeper riser and a shallower tread trade against each other, but only inside narrow limits. With a fixed 10 in tread, adding one riser flattens every step and lengthens the run by another 10 in, which is often the difference between a stair that lands on the patio and one that lands in the flowerbed. Take the flattest step your footprint allows rather than the steepest the code permits: 7 3/4 in is a legal limit, not a target.

What each extra riser buys and costs, on the same 10 in tread

Reading the drawing: what the throat line is telling you

A cut stringer is a board with a staircase bitten out of it. Every notch removes a triangle whose legs are one riser and one tread, and what is left between the inside corner of that notch and the bottom edge of the board is the throat. Cut too deep and the stringer becomes a row of weak spots: the board will still hold the treads, and it will sag or split under a loaded step, usually at the third or fourth notch where the bending is worst.

The arithmetic is a perpendicular distance, not a vertical one. For a 7 3/4 in riser and a 10 in tread the notch takes 6 1/8 in measured square to the board, so an 11 1/4 in 2x12 leaves 5 1/8 in of throat — and that is exactly the 5.1 in depth the American Wood Council says it analysed cut stringers at in DCA 6. On a 9 1/4 in 2x10 the same notch leaves 3 1/8 in, which is why the guide says every deck stair stringer shall be a minimum of 2x12 and why this calculator turns the throat line red rather than quietly printing a number.

When the throat comes out short there are three honest fixes. Use a 2x12 if you were not already. Shorten the rise of each step, which shallows the notch. Or break the stair with a landing, which shortens each flight and lets the guide’s span and notch rules both pass. Shimming the treads up to fake a shallower notch does none of those things and moves the weak spot rather than removing it.

Setting the framing square, then checking the layout

The drawing gives you the square setting directly: hold the square with the tongue on the rise and the blade on the run. For a 6 7/8 in riser and a 10 in tread, that is 6 7/8 on the tongue and 10 on the blade. Step the square up the board, marking the tread cut on the blade and the riser cut on the tongue, and keep the same face against the board every time. Two marks per step, repeated until you run out of risers, and the saw does the rest.

Two cuts are not like the others. The bottom of the stringer loses the thickness of the tread material, so the first riser cut is the unit rise minus the tread thickness — 6 7/8 minus 1 1/2 is 5 3/8 in on a 2x tread. Cut it full height and the first step ends up one tread too high and every step after it is wrong by the same amount. The top of the stringer is cut to sit against the deck framing, plumb and level, at the point the drawing shows.

Before you cut the second stringer, stand the first one up and check it. Put a level on the tread seats, check the first riser against the number, and check the diagonal: the stringer length on the slope is the hypotenuse of total rise and total run, and a tape pulled along the top edge should land within a saw kerf of it. Then use the finished stringer as the pattern for the rest. Two stringers marked independently are two chances to be 1/8 in apart, and 1/8 in of spread between steps is the trip hazard the 3/8 in rule is trying to prevent.

What the cut list covers, and what it does not

The result card gives you the numbers a lumber yard and a saw need: riser count, unit rise, tread count, unit run, total run, stringer length on the slope, throat depth, first riser cut, and the stringer count for your width. The cut list adds the material: how many stringers, how many tread boards at what length, and the square setting for the saw. Print it, or copy it into a note, and the numbers travel to the job site without the phone.

It does not design the connection. Hangers, screws, bolts, post bases, guard posts and the fastening of the stringer to the deck are all decisions with a manufacturer and an inspector in them, and they change with the deck framing, the species and the exposure. It does not check your local amendments either: a state that has adopted a different edition, or a city with its own stair rule, is the authority, not this page. And it does not see the ground, the door swing, the gas line or the window that the stair has to miss.

That is why every limit on this page is shown with the section it came from. If a number here disagrees with your inspector, the inspector is right and the page should be corrected — IRC R311.7 and AWC DCA 6 are quoted, not paraphrased from memory, and the exact sentences are listed in the sources table at the bottom of every page.

Questions people ask before cutting

How do I calculate stair stringers from a total rise?

Divide the total rise by 7 1/2 in and round up to get the number of risers. A 48 in rise gives 6.4, so 7 risers at 6 7/8 in each, and 6 treads cut into the stringer because the deck is the last tread. The stringer length on the slope is the square root of the total rise squared plus the total run squared: for 48 in of rise and 60 in of run that is 76 13/16 in, or 6 ft 4 13/16 in.

What is the throat depth on a cut stringer?

It is the solid wood left between the inside corner of a notch and the bottom edge of the board, measured square to the board. For a 7 3/4 in riser and a 10 in tread the notch removes 6 1/8 in, so a 2x12 at 11 1/4 in leaves 5 1/8 in of throat, which is the 5.1 in depth AWC DCA 6 says it analysed. The same notch in a 2x10 leaves 3 1/8 in, which is why the guide requires a 2x12.

Is a 2x10 strong enough for deck stair stringers?

Not under the prescriptive deck guide. AWC DCA 6 says all stringers shall be a minimum of 2x12, and requires at least three cut stringers on a stair. A 2x10 is a reasonable interior stringer where the notch is shallower and the run shorter, and this calculator will still show you the throat number for one, but it flags a 2x10 on a deck stair as a warning rather than pretending the two are equivalent.

Why does the calculator say 7 risers when I count 6 steps?

Because the top surface is a tread too. A stair that climbs 48 in has 7 rises and 6 treads cut into the stringer; the seventh tread is the deck or floor you arrive on. Count rises on the way up and treads in the stringer, and the two numbers always differ by one. The cut list labels them separately so nobody orders a tread short.

Can I use this for an interior stair?

Yes. Switch the mode to interior and the defaults move to a 2x10 stringer, which is common where the notch is shallower. The same IRC limits apply: 7 3/4 in maximum riser, 10 in minimum tread, 36 in minimum width, 6 ft 8 in of headroom measured from the nosing line, and no more than 3/8 in of difference between the tallest and shortest riser in a flight.

Every limit on this site, with the sentence it came from

LimitValueQuoted textSource
Maximum riser height in a dwelling stair7 3/4 inIRC R311.7.5.1: "The maximum riser height shall be 7 3/4 inches (196 mm)."IRC R311.7 (stairways), free full text, 2012 edition
Largest riser may beat the smallest by no more than3/8 inIRC R311.7.5.1: "shall not exceed the smallest by more than 3/8 inch (9.5 mm)".IRC R311.7 (stairways), free full text, 2012 edition
Minimum tread depth10 inIRC R311.7.5.2: "The minimum tread depth shall be 10 inches (254 mm)."IRC R311.7 (stairways), free full text, 2012 edition
Nosing projection with solid risers3/4 in to 1 1/4 inIRC R311.7.5.3: not less than 3/4 in nor more than 1 1/4 in; not required at a tread depth of 11 in.IRC R311.7 (stairways), free full text, 2012 edition
Minimum headroom over the stair6 ft 8 inIRC R311.7.2: measured vertically from the sloped line adjoining the tread nosings.IRC R311.7 (stairways), free full text, 2012 edition
Minimum clear stair width36 inIRC R311.7.1: not less than 36 in of clear width above handrail height.IRC R311.7 (stairways), free full text, 2012 edition
Landing depth in the direction of travel36 inIRC R311.7.6: for a straight run, not less than 36 in; width not less than the flight width.IRC R311.7 (stairways), free full text, 2012 edition
Maximum rise between landings12 ftIRC R311.7.3: "A flight of stairs shall not have a vertical rise larger than 12 feet."IRC R311.7 (stairways), free full text, 2012 edition
Dressed width of 2x10 and 2x129 1/4 in and 11 1/4 inPS 20 nominal sizes, dressed dimensions as sold.PS 20 American Softwood Lumber Standard — nominal to dressed sizes
Depth AWC analyses a cut stringer at5.1 inDCA 6 commentary: "Cut stringers were analyzed with 5.1" depth which is based on 7.75:10 rise to run ratio." Our own triangle gives the same 5 1/8 in on an 11 1/4 in board.AWC DCA 6 Prescriptive Residential Wood Deck Construction Guide, Stair Requirements (Figures 28–29)
Stringer size, minimum count and spacing2x12, at least 3 cut, 18 in on centreDCA 6: "All stringers shall be a minimum of 2x12"; "If only cut stringers are used, a minimum of three are required"; "maximum spacing of 18" on center".AWC DCA 6 Prescriptive Residential Wood Deck Construction Guide, Stair Requirements (Figures 28–29)
Maximum horizontal span of a solid 2x12 stringer13 ft 3 inDCA 6 commentary: "one-half of the maximum span of 13'-3" permitted for solid stringers".AWC DCA 6 Prescriptive Residential Wood Deck Construction Guide, Stair Requirements (Figures 28–29)

Sources

This is a layout calculator, not a code authority. Every limit shown is quoted from the IRC or from AWC DCA 6, but your state, county or city adopts one edition of the code and may amend it, and an inspector can read a detail differently. Confirm the numbers with your local building department before you cut lumber, and follow the manufacturer for engineered connectors, composite treads and guards.