JoyOne factory · stair layout

Deck Stair Calculator: Stringers, Treads, Risers and the Material List

Enter the height from grade to the finished deck and the width you want. You get the step layout, the number of 2x12 stringers, the tread and riser boards, and a list you can hand to the lumber yard.

Deck presets2x12 stringer ruleFooting pad sizePrintable material list

Stair stringer calculator

6 risers · 5 treads

7" step · 11" tread · throat 5 3/8"

in

Grade to finished deck, or floor to floor. Also accepts 4' 0" or 1220 mm.

in
in

Nosing to nosing. The code minimum is 10 in.

in

Takes the same amount off the bottom riser cut.

Check an existing stair, headroom and nosing
in

Required between 3/4 in and 1 1/4 in when the tread is under 11 in.

in

Tallest riser minus shortest. Leave at 0 for a new layout.

in

Optional. Measured from the nosing line straight up.

Everything is computed in this tab. Nothing you type is uploaded, and the share link keeps the numbers after the #.

Every limit on this page passes6 risers · 5 treads · 7" step · 4' 7" run

Stringers
42x12, 1' 4" on centre
Risers
65 treads
Unit rise
7"178 mm
Tread depth
11"279 mm
Tread boards
459 per tread
Linear feet
45.013.7 m
Stringer length
5' 9 3/16"1758 mm
Throat depth
5 3/8"5 in is the working minimum

Same rise, different count — tap one to redraw

A stair rising 3' 6" over 4' 7": 6 risers at 7" and 5 treads at 11". The stringer is 5' 9 3/16" long on the slope, cut from a 2x12, and the throat under the first notch is 5 3/8".throat 5 ⅜"42"run 55"71132.5° from level
4 stringers at 1' 4" on centre, 6 risers, 5 treads.

Material list

ItemQtySizeHow it is worked out
2x12 stringers46 ft each5' 9 3/16" on the slope, 1' 4" on centre
2x6 tread boards4512 in each9 per tread × 5 treads, 45.0 linear ft
Riser boards455 1/2" tall9 per step across 4' 0" (1x6)
Tread screws402 per stringerStructural screws or hangers rated for the tread; predrill composite

Best tread stock for this layout: 16 ft boards, 3 of them, 6.3% waste. Add 10% for defects and kerf.

Footing at the foot of the stair

AWC DCA 6 shows a mid-span stringer support as a notched 4x4 post on a footing at least 12 in in diameter or 10 in square and 6 in thick, bolted through the stringer with two 1/2 in bolts and washers. Put the same pad under the foot of the stair, below frost where frost moves.

Code checks

  • Riser 7" against the 7 3/4 in maximum

    42 in over 6 risers is 7.000 in per step.

    IRC R311.7.5.1

  • Measured riser spread 0" against the 3/8 in limit

    A layout cut from one number has no spread at all; the check matters when you measure an existing stair.

    IRC R311.7.5.1

  • Tread 11" against the 10 in minimum

    5 treads at 11" gives a 4' 7" total run.

    IRC R311.7.5.2

  • Nosing not required at this tread depth

    At 11" the tread is deep enough that the code drops the nosing requirement, so the riser can be flush.

    IRC R311.7.5.3

  • Width 4' 0" against the 36 in minimum

    4 stringers at 1' 4" on centre.

    IRC R311.7.1

  • Flight rise 3' 6" against the 12 ft limit

    One flight can carry this rise without an intermediate landing.

    IRC R311.7.3

  • Headroom not measured

    Measure from the nosing line straight up to the floor opening; nothing below 6 ft 8 in passes.

    IRC R311.7.2

  • Throat 5 3/8" against the 5 in working depth

    2x12 leaves 5 3/8" of solid wood under the notch, at or above the 5.1 in depth AWC analyses.

    AWC DCA 6

  • Stringer stock 2x12

    At least a 2x12, as DCA 6 requires for deck stairs; at least three cut stringers.

    AWC DCA 6

  • Horizontal span 4' 7" against 13 ft 3 in

    Inside the 13 ft 3 in horizontal span DCA 6 permits for solid 2x12 stringers.

    AWC DCA 6

  • Handrail required on at least one side

    Four or more risers means a graspable handrail, set 34 to 38 in above the nosing line.

    IRC R311.7.8

This is a layout calculator, not a code authority. Every limit shown is quoted from the IRC or from AWC DCA 6, but your state, county or city adopts one edition of the code and may amend it, and an inspector can read a detail differently. Confirm the numbers with your local building department before you cut lumber, and follow the manufacturer for engineered connectors, composite treads and guards.

Three rises, worked out

The same engine that runs in the browser produced this table at build time, so the examples cannot drift from the calculator above.

Worked examples on this page, generated by the same engine the calculator runs
RiseRisersUnit riseTreadsTotal runStringerThroatMaterial
3' 6" rise67"54' 7"5' 9 3/16"5 3/8"4 stringers
4' 6" rise77 11/16"65' 6"7' 1 1/4"4 15/16"4 stringers
5' 6" rise97 5/16"87' 4"9' 2"5 1/8"4 stringers

Produced at build time by the same function the page runs, so the examples cannot drift from the calculator above.

Start at the finished deck surface, and finish the deck first

A deck stair is measured from the ground the stringer bears on to the top of the decking, and both ends of that measurement are easy to get wrong. At the top, the number is the finished walking surface: 5/4 decking is 1 in thick, 2x6 decking is 1 1/2 in, and composite boards vary by manufacturer. Measure to the joist instead and the stair is short by the thickness of the board you have not laid yet. At the bottom, the number is the ground where the stringer actually lands, which is rarely the average grade around the deck.

Build the deck frame before you cut stringers, and lay the decking before you take the final measurement if you can. If the stair has to go in first, measure to the top of the joist and add the decking thickness you have decided on, then write that decision down where the next person will find it. A stair that is 3/4 in out at the top does not fail by 3/4 in at the bottom: it fails by 3/4 in at every step, which is exactly the kind of spread the code limits to 3/8 in.

Check the ground before you commit to a layout. A stair that lands on a slope needs the bottom of each stringer to bear on something solid, and the guide shows the stringer landing on a pad or on a notched post rather than on soil. If the ground falls away steeply, shortening the stair with a landing is often cheaper than building up a pad two feet tall.

How many stringers a deck stair needs

Three is the floor, not a rule of thumb. AWC DCA 6 says that if only cut stringers are used, a minimum of three are required, and that for stairs wider than 36 in a combination of cut and solid stringers may be used at a maximum spacing of 18 in on centre. A 36 in stair therefore gets three stringers at 18 in on centre, a 48 in stair gets four, and a 60 in stair gets five. The calculator applies that rule to the width you type and shows the spacing it used, so a wider stair cannot quietly end up with the same three stringers.

Solid stringers are the ones you buy full length and notch only at the top, with the treads sitting on cleats or in hangers; cut stringers are the sawtooth boards this page draws. Mixing them is allowed within the spacing limit, and it is a common way to keep a wide stair stiff without cutting four identical sawtooth boards. What is not allowed is a 2x10 sawtooth under a deck: the guide requires a minimum of 2x12 for every stringer.

Spacing is measured between stringer centrelines, and the two outside stringers are set in from the edges of the tread. The calculator returns the count and the spacing from the finished width, which assumes the outermost stringers sit flush with the ends of the treads. If you plan to inset them, subtract the inset twice before you use the spacing number.

Stringer counts that follow from the 18 in rule

Footings, pads and what carries the bottom of the stair

The bottom of a deck stringer is a point load, not a distributed one, and it sits on the ground where water collects. The prescriptive detail in DCA 6 shows the stringer bearing on a pad or on a notched 4x4 post, and where a post is used to shorten a long stringer span it is bolted through the stringer with two 1/2 in bolts and washers and centred on a footing 12 in in diameter or 10 in square and 6 in thick. That is the guide’s detail for a mid-span support; the same shape of pad is what most builders put under the foot of the stair.

Two practical points decide whether that pad survives. First, it has to be below the frost line where frost heaves, or the stair will move every spring and the bottom riser will change height by more than the 3/8 in the code allows. Second, the pad has to sit on undisturbed soil or compacted fill, not on the spoil from the deck footings. A stair that settles 1/2 in at the foot is a stair whose first step is now short by 1/2 in, and the fix is to lift the whole stringer rather than to shim the tread.

Where the stair lands on a hard surface — a concrete patio, a paver apron — the stringer still needs bearing, and the cut at the bottom has to sit flat rather than on its point. The calculator gives you the first riser cut shortened by the tread thickness so the first step comes out at the unit rise measured from the surface; it does not know the thickness of your patio slab, so measure from the surface you will actually stand on.

Treads, risers and the hardware between them

Deck treads are usually two 2x6 boards with a small gap, or a single 2x6 plus a ripped board, or a manufactured tread. The calculator works from the dressed board width, not the nominal size: a 2x6 is 5 1/2 in, so a 36 in tread takes seven boards with 1/8 in gaps, and an 11 1/4 in tread depth needs boards cut at 11 1/4 in plus whatever overhang you want past the stringer face.

Riser boards close the gap at the back of each step. They are not required on an exterior stair by the IRC, and open risers are common on decks because they drain and because they let light through, but the opening between treads then has to refuse a 4 in sphere unless the total rise is 30 in or less. On a deck stair with composite treads, follow the manufacturer for the maximum span between stringers and for the fastener: composite expands, and a tight butt joint in summer becomes a buckle in winter.

Fasten treads with structural screws or hangers rated for the load, two per stringer per tread at minimum, and predrill composite. Where the stringer meets the deck, use a hanger or a ledger detail that the guide shows rather than toenailing through the end grain, and keep the fasteners out of the notch root where the wood is already working hardest. The material list on this page counts stringers, tread boards and riser boards; it deliberately does not guess your fastener schedule.

What the printed material list is for

The list exists so the ordering happens once. It gives stringer count and stock size, the tread board count for the width and board you chose, the riser board count, and the linear feet of tread material before waste. Take it to the yard with the total rise and the width written on it, and ask for the grade and treatment your climate needs — ground-contact versus above-ground is a real difference in price and life.

Add waste deliberately. Ten percent is a fair allowance for treads cut from 8, 10, 12 and 16 ft boards, and more if you are matching grain or working around defects. The tread page shows the same numbers as a per-board-length purchase plan, including the offcuts, which is where the waste actually shows up.

The list is not a permit drawing. Guards, stair width, handrail height, the maximum 30 in height before a guard is required on the deck itself, and the connection to the house are all outside it, and they are the parts an inspector will look at first.

Questions people ask before cutting

How many stringers do I need for a 48 inch wide deck stair?

Four. AWC DCA 6 allows a maximum spacing of 18 in on centre for a combination of cut and solid stringers, and requires at least three cut stringers. A 48 in wide stair with stringers flush to the tread ends gives three spaces of 16 in, so four stringers. A 36 in stair needs three at 18 in, and a 60 in stair needs five at 15 in.

Can I use 2x10 stringers on a deck stair?

The prescriptive deck guide says no: all stringers shall be a minimum of 2x12. The reason is the throat. A 7 3/4 in riser and a 10 in tread remove 6 1/8 in of an 11 1/4 in board measured square to it, leaving 5 1/8 in; in a 9 1/4 in 2x10 the same notch leaves 3 1/8 in, which is well under the 5.1 in depth the guide analyses.

How deep should the footing under a deck stair be?

Deep enough to sit below frost where frost moves, and wide enough to carry a point load without settling. DCA 6 shows a mid-span stringer support as a notched 4x4 post on a footing 12 in in diameter or 10 in square and 6 in thick, bolted through the stringer with two 1/2 in bolts. Your local frost depth and soil decide the rest.

Do deck stairs need riser boards?

Not by the IRC on an exterior stair, and many decks leave them open so the stair drains and dries. If the risers are open, the opening between adjacent treads must not pass a 4 in sphere, and that limit is waived only when the total rise is 30 in or less. Closed risers keep leaves and snow out of the stair and make the treads stiffer, at the cost of trapping water if the detail is wrong.

Why is the first step shorter than the others?

Because the tread sits on top of the stringer. The bottom plumb cut has to lose the thickness of the tread material, so a 1 1/2 in tread turns a 7 in unit rise into a 5 1/2 in first riser cut. Measured from the ground to the top of the first tread, the step is still exactly the unit rise. Cut the first riser at full height and every step above it is wrong by the tread thickness.

Every limit on this site, with the sentence it came from

LimitValueQuoted textSource
Maximum riser height in a dwelling stair7 3/4 inIRC R311.7.5.1: "The maximum riser height shall be 7 3/4 inches (196 mm)."IRC R311.7 (stairways), free full text, 2012 edition
Largest riser may beat the smallest by no more than3/8 inIRC R311.7.5.1: "shall not exceed the smallest by more than 3/8 inch (9.5 mm)".IRC R311.7 (stairways), free full text, 2012 edition
Minimum tread depth10 inIRC R311.7.5.2: "The minimum tread depth shall be 10 inches (254 mm)."IRC R311.7 (stairways), free full text, 2012 edition
Nosing projection with solid risers3/4 in to 1 1/4 inIRC R311.7.5.3: not less than 3/4 in nor more than 1 1/4 in; not required at a tread depth of 11 in.IRC R311.7 (stairways), free full text, 2012 edition
Minimum headroom over the stair6 ft 8 inIRC R311.7.2: measured vertically from the sloped line adjoining the tread nosings.IRC R311.7 (stairways), free full text, 2012 edition
Minimum clear stair width36 inIRC R311.7.1: not less than 36 in of clear width above handrail height.IRC R311.7 (stairways), free full text, 2012 edition
Landing depth in the direction of travel36 inIRC R311.7.6: for a straight run, not less than 36 in; width not less than the flight width.IRC R311.7 (stairways), free full text, 2012 edition
Maximum rise between landings12 ftIRC R311.7.3: "A flight of stairs shall not have a vertical rise larger than 12 feet."IRC R311.7 (stairways), free full text, 2012 edition
Dressed width of 2x10 and 2x129 1/4 in and 11 1/4 inPS 20 nominal sizes, dressed dimensions as sold.PS 20 American Softwood Lumber Standard — nominal to dressed sizes
Depth AWC analyses a cut stringer at5.1 inDCA 6 commentary: "Cut stringers were analyzed with 5.1" depth which is based on 7.75:10 rise to run ratio." Our own triangle gives the same 5 1/8 in on an 11 1/4 in board.AWC DCA 6 Prescriptive Residential Wood Deck Construction Guide, Stair Requirements (Figures 28–29)
Stringer size, minimum count and spacing2x12, at least 3 cut, 18 in on centreDCA 6: "All stringers shall be a minimum of 2x12"; "If only cut stringers are used, a minimum of three are required"; "maximum spacing of 18" on center".AWC DCA 6 Prescriptive Residential Wood Deck Construction Guide, Stair Requirements (Figures 28–29)
Maximum horizontal span of a solid 2x12 stringer13 ft 3 inDCA 6 commentary: "one-half of the maximum span of 13'-3" permitted for solid stringers".AWC DCA 6 Prescriptive Residential Wood Deck Construction Guide, Stair Requirements (Figures 28–29)

Sources

This is a layout calculator, not a code authority. Every limit shown is quoted from the IRC or from AWC DCA 6, but your state, county or city adopts one edition of the code and may amend it, and an inspector can read a detail differently. Confirm the numbers with your local building department before you cut lumber, and follow the manufacturer for engineered connectors, composite treads and guards.