JoyOne factory · stair layout

Stair Calculator With Landing: Two Flights, One Riser Height

Give it the total rise and it splits the stair at a landing, keeps both flights on the same riser height, and checks the landing depth and the 12 ft flight limit.

Auto or fixed landingEqual risers both flightsTwo-flight drawingLanding depth check

Two-flight stair calculator

7 + 7 risers

landing at 4' 6" · 14 risers in total

in

Grade to finished deck, or floor to floor. Also accepts 4' 0" or 1220 mm.

in
in

Nosing to nosing. The code minimum is 10 in.

in

Takes the same amount off the bottom riser cut.

in

Leave blank to place the landing at half the rise.

in
Check an existing stair, headroom and nosing
in

Required between 3/4 in and 1 1/4 in when the tread is under 11 in.

in

Tallest riser minus shortest. Leave at 0 for a new layout.

in

Optional. Measured from the nosing line straight up.

Everything is computed in this tab. Nothing you type is uploaded, and the share link keeps the numbers after the #.

Every limit on this page passes14 risers · 13 treads · 7 11/16" step · 10' 10" run

Split
7 + 714 risers in total
Landing height
4' 6"1372 mm
Landing depth
3' 0"36 in minimum
Unit rise
7 11/16"both flights, 0" apart
Lower flight
5' 0"7 risers
Upper flight
5' 0"7 risers
Total footprint
13' 0"3962 mm
Stringers
3 + 3two layouts, two cut lists
Lower flight of 7 risers rises to a landing 4' 6" above grade, then 7 risers climb to the deck. Each flight steps 7 11/16" by 10".108"total run 156"36" landing7 up7 up
7 risers to a landing at 4' 6", then 7 to the deck.

Lower flight

From grade to the landing

Risers
7
Unit rise
7 11/16"196 mm
Treads
6
Total run
5' 0"1524 mm
Stringer
6' 8 3/4"2050 mm
First cut
6 3/16"rise − surface

Square: 7 11/16 on the tongue, 10 on the blade.

Upper flight

From the landing to the deck

Risers
7
Unit rise
7 11/16"196 mm
Treads
6
Total run
5' 0"1524 mm
Stringer
6' 8 3/4"2050 mm
First cut
6 3/16"rise − surface

Square: 7 11/16 on the tongue, 10 on the blade.

Landing checks

  • Two flights differ by 0"

    7 risers up to the landing at 7 11/16", then 7 to the deck at 7 11/16".

    IRC R311.7.5.1

  • Landing 3' 0" deep by 3' 0" wide

    At least 36 in in the direction of travel and no narrower than the flight it serves.

    IRC R311.7.6

  • Each flight inside the 12 ft limit

    4' 6" below the landing, 4' 6" above it.

    IRC R311.7.3

This is a layout calculator, not a code authority. Every limit shown is quoted from the IRC or from AWC DCA 6, but your state, county or city adopts one edition of the code and may amend it, and an inspector can read a detail differently. Confirm the numbers with your local building department before you cut lumber, and follow the manufacturer for engineered connectors, composite treads and guards.

Three rises, worked out

The same engine that runs in the browser produced this table at build time, so the examples cannot drift from the calculator above.

Worked examples on this page, generated by the same engine the calculator runs
RiseRisersUnit riseTreadsTotal runStringerThroatMaterial
9' 0" rise147 11/16"1310' 10"14' 1"5 1/8"3 stringers
10' 0" rise167 1/2"1512' 6"16' 1/16"5 1/4"3 stringers
11' 0" rise187 5/16"1714' 2"17' 11 1/4"5 5/16"3 stringers

Produced at build time by the same function the page runs, so the examples cannot drift from the calculator above.

When a stair needs a landing, and when it only wants one

There are three reasons to put a landing in a stair, and they are worth separating because they have different thresholds. The first is the code: a flight of stairs may not rise more than 12 ft between floor levels or landings, so a stair climbing 13 ft has to be broken. The second is a change of direction: an L-shaped or switchback stair needs a landing at the turn, and that landing has to be at least as wide as the flights it serves and at least 36 in deep in the direction of travel. The third is practical: a long single flight is a long piece of lumber, and 2x12 stock stops being straight somewhere around 16 ft.

A landing also solves the case the code does not mention: a door at the top or bottom. A door that swings over a stair is a hazard, and the IRC exception that lets an interior flight skip a top landing only holds while the door does not swing over the stairs. Adding 36 in of landing is often the cheapest way to make a door work.

What a landing does not do is make a steep stair acceptable. It breaks the rise into two flights, and both flights still have to satisfy the 7 3/4 in riser and 10 in tread limits on their own. If the single flight was failing the riser check, splitting it does not fix that unless the total riser count also goes up.

Splitting the rise so both flights step the same

The rule that matters is that every riser in the stair is the same height, including the one onto the landing and the one off it. So the landing is not at half the total rise: it is at a whole number of risers above grade. For a 108 in rise the count is 14 risers at 7 11/16 in, and a landing after 7 of them sits at exactly 54 in — the halfway case falls out cleanly because the riser count is even. Take the same rise with 15 risers at 7.2 in each and there is no halfway point at all: the landing has to be after 7 risers (50.4 in) or after 8 (57.6 in), and either one is correct while the arithmetic half is not. Put the landing at a round 54 in on that layout and you have created two flights with different riser heights, which is exactly the defect the 3/8 in rule exists to prevent.

This calculator takes the total rise, picks the riser count that clears the 7 3/4 in limit, and then places the landing at the nearest whole riser to the middle. You can also type the landing height you want, and it will find the nearest compliant split and show the difference between the two flights, which is zero when the split lands on a whole riser and non-zero when it does not. Both numbers are printed so the choice is visible rather than hidden in a rounding step.

Equal flights are convenient but not required. What is required is equal risers. A stair that climbs 8 risers to the landing and 5 above it is legal and sometimes the only way to fit a door or a window, as long as all 13 risers are the same height and each flight stays inside the 12 ft limit.

Landing size, support and the post underneath

A landing is a small deck, and it is built like one. The IRC requires a landing at the top and bottom of each stairway, at least as wide as the flight it serves, and at least 36 in deep in the direction of travel for a straight run. For a stair that turns, the landing has to be at least as deep at the walk line as a quarter circle whose radius equals the required width, which is a wordy way of saying a corner landing has to be big enough to turn in with the treads it replaces.

Underneath, a mid-height landing carries the same point loads as the foot of a stair, and the guide treats an intermediate landing as a non-ledger deck with its own posts and footings. Two posts at the outer corners, footings sized for the load and the frost depth, and a frame that does not rely on the stringers for lateral support. Bolting a landing to the stringers and calling it supported is the failure mode to avoid.

The landing also changes the guard question. A landing more than 30 in above grade needs a guard on its open sides, at least 36 in high with balusters that refuse a 4 in sphere, and the guard posts take a 200 lb concentrated load at the top. None of that is in the stair arithmetic, and all of it is inspected.

Headroom is measured from the nosing line, not the floor

The 6 ft 8 in headroom rule is measured vertically from the sloped line that joins the tread nosings to the underside of the floor opening above. That line is higher at the top of the stair than at the bottom, so the critical point is usually the first tread under the opening, not the last. A stair that looks fine standing at the bottom can still have someone hit their head two steps in.

Adding a landing changes the geometry twice: it raises the point where the upper flight passes under the opening, and it moves the opening itself if the plan changes. Measure the headroom after the landing height is fixed, at the tread that sits directly under the lowest edge of the opening, and remember the IRC exception that lets the floor opening project up to 4 3/4 in into the headroom where tread nosings extend under its edge.

On an exterior deck stair there is usually no opening to hit, so headroom is a non-issue until the stair passes under a deck or a roof. Where it does, the same 6 ft 8 in applies, and the landing is often what makes it achievable.

Two flights means two layouts, and one of them is upside down

The lower flight is laid out from the ground up: bottom cut shortened by the tread thickness, then riser and tread marks to the landing. The upper flight starts at the landing and climbs to the deck, so its bottom cut is shortened by the landing surface thickness — decking or a concrete slab — rather than by a tread. Get that wrong and the first step off the landing is short by the thickness of the landing surface.

The two flights also share a unit rise but not a stringer length. The lower flight’s stringer length is the hypotenuse of its own rise and run, and the upper flight’s is the hypotenuse of the rest. If the flights are unequal the two stringers are different lengths, which is fine but worth writing on the cut list, because a pair of precut stringers bought for a symmetric stair will not fit an asymmetric one.

Finally, the landing has to be framed square and level before either stringer is cut. A landing that is 1/4 in out of level across its width gives one stringer a different riser from the other, and that is a 1/4 in spread the moment you walk across the stair.

Questions people ask before cutting

How do I calculate a stair with a landing?

Decide the total rise, pick the riser count that keeps every riser at or under 7 3/4 in, then put the landing at a whole number of risers, usually close to half. For a 108 in rise, 14 risers at 7 11/16 in each put a landing after 7 risers at exactly 54 in. Both flights then use the same 7 11/16 in riser, and each flight is checked against the 12 ft flight limit separately.

Should the landing be exactly halfway up?

No — it should be a whole number of risers up, which is usually within half a riser of halfway. The landing height is a riser count times the unit rise, so an odd riser count has no exact halfway point: 15 risers of 7.2 in land at 50.4 in or 57.6 in, never at 54 in. Forcing a round number creates two different riser heights in the same stair.

How big does a stair landing have to be?

At least as wide as the flight it serves, and at least 36 in deep in the direction of travel for a straight run. A landing at a turn has to be at least as deep at the walk line as a quarter circle with a radius equal to the required width. Where a door opens onto the landing, the door may not reduce the landing below half its required width.

Is a landing required for a stair over 12 feet?

Yes. IRC R311.7.3 limits a flight to a 12 ft vertical rise between floor levels or landings, so any stair climbing more than that has to be broken by an intermediate landing. The landing itself has to meet the depth and width rules, and it has to be framed and supported like the small deck it is.

Does the landing surface thickness change the first step?

Yes. The bottom plumb cut of each stringer is shortened by the thickness of the surface the tread sits on, so the upper flight’s first cut is reduced by the landing surface — decking, pavers or a slab — not by a tread. Measure from the finished landing surface and cut the bottom riser to the unit rise minus that thickness.

Every limit on this site, with the sentence it came from

LimitValueQuoted textSource
Maximum riser height in a dwelling stair7 3/4 inIRC R311.7.5.1: "The maximum riser height shall be 7 3/4 inches (196 mm)."IRC R311.7 (stairways), free full text, 2012 edition
Largest riser may beat the smallest by no more than3/8 inIRC R311.7.5.1: "shall not exceed the smallest by more than 3/8 inch (9.5 mm)".IRC R311.7 (stairways), free full text, 2012 edition
Minimum tread depth10 inIRC R311.7.5.2: "The minimum tread depth shall be 10 inches (254 mm)."IRC R311.7 (stairways), free full text, 2012 edition
Nosing projection with solid risers3/4 in to 1 1/4 inIRC R311.7.5.3: not less than 3/4 in nor more than 1 1/4 in; not required at a tread depth of 11 in.IRC R311.7 (stairways), free full text, 2012 edition
Minimum headroom over the stair6 ft 8 inIRC R311.7.2: measured vertically from the sloped line adjoining the tread nosings.IRC R311.7 (stairways), free full text, 2012 edition
Minimum clear stair width36 inIRC R311.7.1: not less than 36 in of clear width above handrail height.IRC R311.7 (stairways), free full text, 2012 edition
Landing depth in the direction of travel36 inIRC R311.7.6: for a straight run, not less than 36 in; width not less than the flight width.IRC R311.7 (stairways), free full text, 2012 edition
Maximum rise between landings12 ftIRC R311.7.3: "A flight of stairs shall not have a vertical rise larger than 12 feet."IRC R311.7 (stairways), free full text, 2012 edition
Dressed width of 2x10 and 2x129 1/4 in and 11 1/4 inPS 20 nominal sizes, dressed dimensions as sold.PS 20 American Softwood Lumber Standard — nominal to dressed sizes
Depth AWC analyses a cut stringer at5.1 inDCA 6 commentary: "Cut stringers were analyzed with 5.1" depth which is based on 7.75:10 rise to run ratio." Our own triangle gives the same 5 1/8 in on an 11 1/4 in board.AWC DCA 6 Prescriptive Residential Wood Deck Construction Guide, Stair Requirements (Figures 28–29)
Stringer size, minimum count and spacing2x12, at least 3 cut, 18 in on centreDCA 6: "All stringers shall be a minimum of 2x12"; "If only cut stringers are used, a minimum of three are required"; "maximum spacing of 18" on center".AWC DCA 6 Prescriptive Residential Wood Deck Construction Guide, Stair Requirements (Figures 28–29)
Maximum horizontal span of a solid 2x12 stringer13 ft 3 inDCA 6 commentary: "one-half of the maximum span of 13'-3" permitted for solid stringers".AWC DCA 6 Prescriptive Residential Wood Deck Construction Guide, Stair Requirements (Figures 28–29)

Sources

This is a layout calculator, not a code authority. Every limit shown is quoted from the IRC or from AWC DCA 6, but your state, county or city adopts one edition of the code and may amend it, and an inspector can read a detail differently. Confirm the numbers with your local building department before you cut lumber, and follow the manufacturer for engineered connectors, composite treads and guards.